All case studies
Interferometry

Michelson and Mach-Zehnder interferometers

Fringes, visibility and coherence against textbook results

Michelson and Mach-Zehnder interferometers

Michelson and Mach-Zehnder interferometers in laser

mode, compared with textbook results

He-Ne laser, each arm propagated as a wave: fringe count, gas index, visibility and coherence, fringe

period, rings and energy balance

QuestionReference and method
Does etendue compute the fringes of an interferometerAn open textbook gives the Michelson results: one fringe
correctly when it propagates each arm as a wave?per half wavelength of mirror travel, and a gas index from
Designers of metrology and alignment benches read the122 fringes [1]. Two-beam interference gives the
fringe count, the visibility, the coherence length and thevisibility, equal to the degree of coherence, and the
fringe period from these maps. This note compares themfringe period of a tilted mirror [2]. A lossless Mach-
with the Michelson results of a published textbook andZehnder with equal arms sends all the light to one output
with closed-form results of two-beam interference.[3]. In etendue each arm is propagated as a wave to the

detector, where the fields are added. The agreement criteria were set before the measurement.

1 The systems

PARAMETER VALUE PARAMETER VALUE

Source He-Ne laser, 632.8 nm, 2 mW, line width 0.002 nm Michelson arms 100 mm, 50/50 beam splitter, plane mirrors

Beam 1 mm radius at 1/e², expanded 5× to 5 mm Detector 50 mm after the beam splitter

Mach-Zehnder two 50/50 beam splitters, equal arms Propagation each arm as a wave, fields added at the detector

Table 1. The interferometers as entered in etendue in laser mode. For each test the system is modified as a user would do it: a mirror moved or tilted, a gas cell added, the expander removed, a spherical mirror.

2 Deviation of each quantity from its reference

Figure 1. Deviation of etendue from the reference, one point per case, against the agreement criterion of each quantity (black tick). Points at 10⁻¹³ or below agree to machine precision. The coherence length is 132.996 mm against 133.001 mm for the definition etendue states.

32 / 321.9×10⁻¹¹5.7×10⁻⁷0.5036 mm
Quantities within theLargest error on the fringeLargest error on the fringeFringe period for a mirror
agreement criterion writtencount, in fringes, for mirrorvisibility for path differencestilted by 0.036°, against
before the measurement.displacements up to 1000up to 300 mm.0.5036 mm in theory.

fringes.

etendue.io Michelson and Mach-Zehnder · He-Ne 632.8 nm · wave-optics propagation · etendue, November 2026

Results against the published references

32 of 32 quantities within their criteria

Table 2. Deviation by quantity, all cases

LARGEST Verdict

QUANTITY VALUES DEVIATION CRITERION VERDICT All 32 quantities judged meet the criteria Fringe count (fringes) 6 1.9×10⁻¹¹ 0.001 met written before the measurement. Fringe counts agree to about 10⁻¹¹ fringe and the Intensity, bright and dark 2 4.5×10⁻¹² 10⁻⁵ met visibility to better than 10⁻⁶, far inside the Visibility 6 5.7×10⁻⁷ 10⁻⁴ met criteria. Degree of coherence 6 < 10⁻¹⁵ 10⁻⁴ met The gas cell gives 122.000000000 fringes Coherence length (rel.) 1 3.6×10⁻⁵ 0.001 met for 122 published, and an index of 1.0019. Fringe period (rel.) 2 2.9×10⁻⁶ 10⁻⁴ met Its faces carry an ideal anti-reflection coating: the reference assumes walls that Fringe orientation (°) 2 1.2×10⁻¹¹ 0.01 met are the same with the cell empty or full, MZ, dark output share 1 1.2×10⁻¹² 10⁻⁹ met whereas a bare gas–air face reflects

MZ, energy balance (rel.)19.0×10⁻¹³10⁻⁹ metabout 9×10⁻⁷ when full and nothing when
MZ, complementary outputs14.0×10⁻¹⁰10⁻⁶ metempty.
^(R)^(i)^(n)^(g)^(s)^(,)^(d)^(i)^(v)^(e)^(r)^(g)^(i)^(n)^(g)^(b)^(e)^(a)^(m)^(()^(r)^(e)^(l)^(.)^())^(1)^(1)^(.)^(0)^(×)^(1)^(0)^(⁻)^(³)^(0)^(.)^(0)^(1)^(m)^(e)^(t)What a user should know

Rings, spherical mirror (rel.) 1 8.6×10⁻⁴ 0.01 met The Michelson as delivered, with its beam Gas cell (fringes; index) 2 3.7×10⁻¹¹ 0.001 met expander, gives a fringe period of 1.0063

Largest absolute deviation over the cases, in the unit of the row (relative wheremm for 1.0071 mm with plane waves. The
stated). Cases: mirror moved by 0, 0.1575, 0.315, 3.15, 31.5 and 315 μm at 630 nm; pathdifference comes from the wavefront that
differences of 0 to 300 mm; mirror tilted by 0.018° and 0.036° in a parallel 10 mmthe expander leaves on the beam, which
beam; rings with a diverging beam (mirror moved 30 mm) and with a 20 m sphericalthe textbook does not have.

mirror. MZ: Mach-Zehnder. The coherence length depends on its Table 3. Fringe visibility and coherence, 0.002 nm line^(d)^(e)^(f)^(i)^(n)^(i)^(t)^(i)^(o)^(n)^(.)^(F)^(o)^(r)^(t)^(h)^(e)^(s)^(a)^(m)^(e)^(0)^(.)^(0)^(0)^(2)^(n)^(m)^(l)^(i)^(n)^(e)^(i)^(t)^(i)^(s) 133 mm by the definition etendue states Path difference (mm) |γ|, reference Coherence, etendue Visibility, etendue (Mandel), 177 mm at half-height of |γ| and 0 1.000000 1.000000 1.000000 200 mm as λ²/Δλ. The visibility at a given 50 0.800917 0.800917 0.800917 path difference does not depend on it.

^(1)^(0)^(0)^(0)^(.)^(4)^(1)^(1)^(4)^(8)^(2)^(0)^(.)^(4)^(1)^(1)^(4)^(8)^(2)^(0)^(.)^(4)^(1)^(1)^(4)^(8)^(1) Limits of validity

133 0.207886 0.207886 0.207885 With a spherical end mirror, the ring 200 0.028668 0.028668 0.028668 spacing is 0.7 to 0.9% below the two- 300 0.000338 0.000338 0.000338 spherical-wave result, for convex and concave mirrors of 5 and 20 m. That |γ| = exp(−(πΔν·OPD/c)²/(4 ln 2)) for a Gaussian line of width Δν. The visibility is result assumes a parallel beam, and the slightly below |γ| because the two beams no longer have the same size and curvature beam expander of the Michelson leaves a when one arm is longer. spherical aberration of about 0.1 wave at References. [1] S. J. Ling, J. Sanny, W. Moebs, University Physics, Vol. 3, OpenStax the beam radius. Recomputed by exact (2016), § 3.6 “The Michelson Interferometer”: Example 3.6.1 (315 nm per fringe at 630 ray tracing through the expander, outside nm), “Measuring the refractive index of a gas” (2 cm, 122 fringes, n = 1.0019) and etendue, the reference for the 20 m mirror Exercise 3.6.1. [2] S. Konijnenberg, A. J. L. Adam, H. P. Urbach, BSc Optics, TU Delft, § differs from etendue by +0.09%. Without 5.5 “Temporal coherence and the Michelson interferometer”: I = 2I₀{1 + Re[γ(τ) the expander, with a parallel 10 mm beam, exp(ikxx)]} and the Wiener-Khinchine theorem, from which V = |γ|, |γ| of a Gaussian the two-wave result holds to 0.02%. line and the period λ/sin 2α of a mirror tilted by α. [3] Physics LibreTexts, “The Mach- Zehnder Interferometer”. Ring spacing of two spherical waves of radii R₁, R₂: Δ(r²) = The references assume ideal, lossless 2λ/|1/R₁ − 1/R₂|. beam splitters and a single-mode source with a Gaussian line. Polarisation effects of the beam splitter are not compared.

etendue.io Interference analysis of etendue, laser mode · reference values from the published results and closed-form two-beam

interference